{"product_id":"electric-radiant-floor-heating-cables-used-with-ditra-heat-membrane","title":"Electric Radiant Floor Heating Cables used with DITRA-HEAT Membrane","description":"\u003cdiv\u003e\u003cstrong\u003eElectric Radiant Floor Heating Cables used with DITRA-HEAT Membrane\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eSchluter\u003csup class=\"regsign\"\u003e® \u003c\/sup\u003eDITRA-HEAT-E-HK are twisted pair heating cables designed for integration with the DITRA-HEAT uncoupling membrane in interior floor warming applications.\u003c\/div\u003e\n\u003cul class=\"product__specs is-active\"\u003e\n\u003cli class=\"product__listitem\"\u003eCables snap into the membrane; clips and fasteners are not required\u003c\/li\u003e\n\u003cli class=\"product__listitem\"\u003eNo self-levelers required to encapsulate the cables; installation time significantly reduced\u003c\/li\u003e\n\u003cli class=\"product__listitem\"\u003eNo return to thermostat required\u003c\/li\u003e\n\u003cli class=\"product__listitem\"\u003eProduces virtually zero electromagnetic fields\u003c\/li\u003e\n\u003cli class=\"product__listitem\"\u003e120 V\u003c\/li\u003e\n\u003cli class=\"product__listitem\"\u003eProvides electric floor warming for use beneath tile, stone, or other resilient floor coverings (e.g. LVT)\u003c\/li\u003e\n\u003cli class=\"product__listitem\"\u003eNote: Two floor temperature sensors are provided with the heating cables. These can be installed at the same time as the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCable Area and Included Cable Length\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 m² (10.7 ft²) comes with 35.3 linear length of cable\u003c\/li\u003e\n\u003cli\u003e1.5 m² (16.0 ft²) comes with 52.9 linear length of cable\u003c\/li\u003e\n\u003cli\u003e2 m² (21.3 ft²) comes with 70.5 linear length of cable\u003c\/li\u003e\n\u003cli\u003e2.5 m² (26.7 ft²) comes with 88.2 linear length of cable\u003c\/li\u003e\n\u003cli\u003e3 m² (32.0 ft²) comes with 105.8 linear length of cable\u003c\/li\u003e\n\u003cli\u003e3.5 m² (37.5 ft²) comes with 124.1 linear length of cable\u003c\/li\u003e\n\u003cli\u003e4 m² (51.4 ft²) comes with 141.1 linear length of cable\u003c\/li\u003e\n\u003cli\u003e4.8 m² (51.4 ft²) comes with 169.8 linear length of cable\u003c\/li\u003e\n\u003cli\u003e6 m² (64.4 ft²) comes with 212.9 linear length of cable\u003c\/li\u003e\n\u003cli\u003e6.8 m² (72.7 ft²) comes with 240.2 linear length of cable\u003c\/li\u003e\n\u003cli\u003e7.7 m² (83.3 ft²) comes with 275.5 linear length of cable\u003c\/li\u003e\n\u003cli\u003e8.5 m² (91.7 ft²) comes with 303.0 linear length of cable\u003c\/li\u003e\n\u003cli\u003e9.5 m² (101.9 ft²) comes with 336.9 linear length of cable\u003c\/li\u003e\n\u003cli\u003e10.5 m² (112.6 ft²) comes with 372.2 linear length of cable\u003c\/li\u003e\n\u003cli\u003e12.5 m² (134.5 ft²) comes with 444.0 linear length of cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANT Ordering Information for Schluter®-DITRA-HEAT Cables\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDo not purchase a heating cable that is the same size as the area to be tiled; you will be left with too much heating cable!\u003c\/li\u003e\n\u003cli\u003eVery important: Never CUT or modify the heating cable in any way. This would change the cable resistance, will cause damage to the cable, and could cause cable overheating.\u003c\/li\u003e\n\u003cli\u003eA cable spacing of 3 studs is standard.\u003c\/li\u003e\n\u003cli\u003eCable may also be spaced at continuously alternating 3 stud – 2 stud intervals in isolated areas or over the entire floor. This practice may be desirable to increase heat output (e.g., over uninsulated on or below grade concrete subfloors) or to consume more cable length in a given area (e.g., when using the standard 3 stud spacing doesn’t allow the selected cable to fit the floor area and respect minimum spacing requirements from walls, partitions, etc.)\u003c\/li\u003e\n\u003cli\u003eA cable spacing of 4 studs is not recommended, as it can produce inconsistent floor surface temperatures.\u003c\/li\u003e\n\u003cli\u003eMinimum spacing from walls, partitions, and fixed cabinets is 2\" (50 mm).\u003c\/li\u003e\n\u003cli\u003eMinimum spacing from other heat sources (baseboard heaters, other fixed heating devices, fireplaces, etc.) is 8\" (200 mm).\u003c\/li\u003e\n\u003cli\u003eMinimum spacing from any plumbing drain and forced air heating duct  is 4\" (100 mm).\u003c\/li\u003e\n\u003cli\u003eMinimum spacing from centerline of toilet drains is 7\" (180 mm).\u003c\/li\u003e\n\u003cli\u003eNEVER install the heating cable under vanities with no air space beneath, bathtub platforms, free standing bathtubs with no air space beneath, kitchen cabinets and islands, any other fixtures in storage or clothing closets. Excessive heat will build up in these confined spaces and may cause cable overheating.\u003c\/li\u003e\n\u003cli\u003eNEVER install the heating cable under or through a wall, partition, or through a floor.\u003c\/li\u003e\n\u003cli\u003eNEVER install the factory splice (i.e., black plastic junction between the cold lead and gray heating cable) in the wall. This will cause overheating, system failure, and could cause damage. This splice must be installed entirely under the floor covering, as shown in the heating cable installation instructions.\u003c\/li\u003e\n\u003cli\u003eIt is helpful to plan the location of a buffer zone, as it is not always possible to predict where the heating cable will end. The buffer zone is an area where heating is not essential, typically behind a toilet or adjacent to a door opening. This area allows for placement of excess heating cable. Heating cables may also be installed 6\" (150 mm) from the wall to create a buffer zone.\u003c\/li\u003e\n\u003cli\u003eHeating cable testing is required while the heating cable is on the spool and at two subsequent steps during installation to ensure cable quality and for warranty purposes. A megohmmeter is required for the insulation resistance testing of the heating cables. Insulation resistance testing is strongly recommended.\u003c\/li\u003e\n\u003cli\u003eConsult a qualified electrician before ordering DITRA-HEAT heating cables to ensure you order the correct voltage for your installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer: SCHLUTER, DITRA, DITRA-HEAT are trademarks of Schluter-Systems. The Original Granite Bracket is not affiliated with Schluter-Systems. The Original Granite Bracket products are not manufactured, distributed, warranted or endorsed by Schluter-Systems.\u003c\/strong\u003e\u003c\/p\u003e","brand":"The Original Granite Bracket","offers":[{"title":"120v \/ 35.3 lf.\/ coverage 10.7ft","offer_id":54057023504752,"sku":"DHEHK12011","price":179.33,"currency_code":"USD","in_stock":true},{"title":"120v \/ 52.9 lf.\/ coverage 16.0ft","offer_id":54057023537520,"sku":"DHEHK12016","price":199.92,"currency_code":"USD","in_stock":true},{"title":"120v \/ 70.5 lf.\/ coverage 21.3ft","offer_id":54057023570288,"sku":"DHEHK12021","price":239.85,"currency_code":"USD","in_stock":true},{"title":"120v \/ 88.2 lf.\/ coverage 26.7ft","offer_id":54057023603056,"sku":"DHEHK12027","price":257.58,"currency_code":"USD","in_stock":false},{"title":"120v \/ 105.8 lf.\/ coverage 32ft","offer_id":54057023635824,"sku":"DHEHK12032","price":278.7,"currency_code":"USD","in_stock":true},{"title":"120v \/ 124.1 lf.\/ coverage 37.5ft","offer_id":54057023668592,"sku":"DHEHK12038","price":298.67,"currency_code":"USD","in_stock":false},{"title":"120v \/ 141.1 lf.\/ coverage 42.7ft","offer_id":54057023701360,"sku":"DHEHK12043","price":316.12,"currency_code":"USD","in_stock":true},{"title":"120v \/ 169.8 lf.\/ coverage 51.4ft","offer_id":54057023734128,"sku":"DHEHK12051","price":355.08,"currency_code":"USD","in_stock":false},{"title":"120v \/ 212.9 lf.\/ coverage 64ft","offer_id":54057023766896,"sku":"DHEHK12064","price":393.79,"currency_code":"USD","in_stock":true},{"title":"120v \/ 240.2  lf.\/ coverage 72.7ft","offer_id":54057023799664,"sku":"DHEHK12073","price":432.84,"currency_code":"USD","in_stock":false},{"title":"120v \/ 275.5  lf.\/ coverage 83.3ft","offer_id":54057023832432,"sku":"DHEHK12083","price":485.45,"currency_code":"USD","in_stock":false},{"title":"120v \/ 303.0 lf.\/ Coverage 91.7 ft","offer_id":54057023865200,"sku":"DHEHK12092","price":529.98,"currency_code":"USD","in_stock":true},{"title":"120v \/ 336.9 lf.\/ coverage 101.9ft","offer_id":54057023897968,"sku":"DHEHK120102","price":583.19,"currency_code":"USD","in_stock":true},{"title":"120v \/ 372.2 lf.\/ coverage 112.6ft","offer_id":54057023930736,"sku":"DHEHK120113","price":636.89,"currency_code":"USD","in_stock":true},{"title":"120v \/ 444.0 lf.\/ coverage 134.3ft","offer_id":54057023963504,"sku":"DHEHK120134","price":696.82,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/4157\/6048\/files\/DitraHeat-Cable-CurvedWire_3.jpg?v=1784655786","url":"https:\/\/stonetiledepot.myshopify.com\/products\/electric-radiant-floor-heating-cables-used-with-ditra-heat-membrane","provider":"Stonetiledepot","version":"1.0","type":"link"}